Gearmotors.ca is published by SEW-EURODRIVE Canada. Product examples refer to SEW-EURODRIVE; the guidance applies to equipment from any manufacturer. About this site
Short answer: You can add condition monitoring to gearmotors already in service without replacing them. The usual options are bolt-on vibration and temperature sensors, wireless sensor kits, oil analysis, and the current and load data that many variable frequency drives already record. The hardware is rarely the hard part: monitoring only pays off once alerts reach the maintenance and control systems your teams already use, so plan the CMMS or SCADA connection from the start.
Can you add condition monitoring to an existing gearmotor?
Yes. Most retrofit options mount externally or need no hardware at all:
| Option | What it tracks | Best for | Limitations |
|---|---|---|---|
| Bolt-on wired sensors | Vibration and temperature at bearings or housing | Critical units close to existing control wiring | Cabling cost and installation time |
| Wireless sensor kits | Vibration and temperature, sent to a gateway | Units spread across a site, or where new wiring is impractical | Battery life, radio range in metal-heavy plants, and cold-weather ratings |
| Oil analysis | Wear particles, contamination, water and lubricant condition | Any oil-lubricated gear unit; no hardware needed | Periodic snapshots rather than continuous data |
| Drive (VFD) data | Motor current, load, speed and drive temperature | Gearmotors already on a variable frequency drive | Indirect: shows the effect of a problem rather than its exact location |
Many plants combine two: continuous vibration and temperature on the most critical units, and scheduled oil analysis across the rest.

Where should sensors go on a gearmotor?
- Mount vibration sensors on solid housing surfaces as close as possible to the bearings, not on thin covers, fins or guards.
- Monitor the input (motor side) and output bearings on larger gear units, since faults often develop at one end first.
- Use the same mounting points every time if you take handheld readings, so trends compare like with like.
- For outdoor or unheated Canadian sites, check each sensor’s and gateway’s rated operating temperature and battery performance in cold weather before buying.
What are the limits of retrofit monitoring?
Retrofit sensors usually capture fewer measurement points than monitoring built in at the factory, and their accuracy depends on correct placement on the existing housing. They also need baselines: collect readings while the unit is known to be healthy, and in seasonal or unheated facilities, collect them in both warm and cold conditions so normal winter readings don’t trigger false alarms.
How do you connect monitoring data to CMMS and SCADA?
- CMMS (computerized maintenance management system): condition alerts automatically create work orders, so nobody has to notice that a threshold was crossed.
- SCADA: equipment health appears alongside process data, so operators see drive condition in the same view as production.
Common connection routes include OPC UA and MQTT, or the monitoring vendor’s own integration with your CMMS. Ask vendors early which systems they connect to directly.
Why do condition monitoring projects stall?
The usual reason is not the sensors. It’s that the data ends up on a separate dashboard nobody checks. To avoid that:
- Name an owner for each alarm and agree how fast they respond.
- Set thresholds that reflect each unit’s baseline, to avoid alarm fatigue.
- Route alerts into the CMMS as work orders from day one.
- Review false alarms and missed failures every few months and adjust.
What can you do before a full retrofit?
Two low-cost practices give early warning even with no sensors installed:
- Periodic oil analysis: flags contamination and wear particles early, and is one of the cheapest predictive signals available for gear units.
- Routine handheld checks: a regular route with a handheld vibration meter and infrared thermometer or thermal camera, taken at the same points each time, builds the trend history that later justifies permanent sensors.
Where SEW-EURODRIVE fits in
As one example, SEW-EURODRIVE Canada’s DriveRadar® IoT Suite adds condition monitoring to industrial gear units using plug-and-play smart sensors, edge processing and alerts, with data viewable from a smart device. For older drive technology more broadly, SEW-EURODRIVE Canada’s Retrofit Service includes analysis of installed drive technology, including products from other manufacturers.
Related reading
Last reviewed: October 2026